← Table of contents
Scientific American Supplement, No. 467, December 13, 1884

BOILER TUBES.

Reading edition

The following table gives the draught area and heating surface of the various sized boiler tubes and flues:

External Diameter. Draught area in sq. inches. Draught Area in sq. feet. Heating surface in feet per ft. of tube in length. No. of tubes in 1 sq. foot of draught area.

5/8 ...... ...... .1636 .....

¾ ...... ...... .1963 .....

1 .575 .0040 .2618 250.0

1¼ .968 .0067 .3272 149.3

1½ 1.389 .00964 .3927 103.7

1¾ 1.911 .0133 .4581 75.2

2 2.573 .0179 .5236 55.9

2¼ 3.333 .0231 .5891 43.3

2½ 4.083 .0284 .6545 35.2

2¾ 5.027 .0349 .7200 28.7

3 6.070 .0422 .7854 23.7

3¼ 7.116 .0494 .8508 20.2

3½ 8.347 .0580 .9163 17.2

3¾ 9.676 .0672 .9818 14.9

4 10.93 .0759 1.0472 13.2

4½ 14.05 .0996 1.1781 10.2

5 17.35 .1205 1.3090 8.3

6 25.25 .1753 1.5708 5.7

7 34.94 .2426 1.8326 4.1

8 46.20 .3208 2.0944 3.1

9 58.63 .4072 2.3562 2.5

10 72.23 .5016 2.6180 2.0