The coil to be described is 3-1/2 in., full length of iron core, and 3/4 in. in diameter.

Procure a bundle of small iron wire, say 1/4 in. in diameter, and cut it 3-1/2 in. long; bind neatly with coarse thread and file the ends smooth (Fig. 1). This done, make two wood ends, 1-1/4 by 1-1/4 in. and 3/8 in. thick, and varnish. Bore holes in the center of each so the core will fit in snugly and leave about 1/4 in. projecting from each end (Fig. 1).

After finishing the core, shellac two layers of thick paper over it between the ends; let this dry thoroughly. Wind two layers of bell magnet wire over this, allowing several inches of free wire to come through a hole in the end. Cover with paper and shellac as before.

Wind about 1/8 in. of fine wire, such as used on telephone generators, around the coil, leaving long terminals. Soak the whole in melted paraffin and let cool; bind tightly with black silk.

The vibrator is made of a piece of thin tin to which is soldered the head of an iron screw and on the other side a small piece of platinum, which can be taken from an old electric bell (Fig. 2).

Of course, a regulator must be had for the vibrator; this can be accomplished by bending a stout piece of copper wire as shown. The connections and the base for setting up are shown in the figures.

Contributed by J. T. R., Washington, D. C.