These temperature corrections are for a Brix instrument standardized for 20°C. There are Brix hydrometers on the market standardized for 17.5°C. Temperature corrections for a Brix hydrometer standardized at this temperature may be obtained by correcting to 20° by means of the above table (for instrument graduated at 20°C.) and adding to this corrected reading 0.12. For instance suppose the reading for a 17.5° instrument is 7.00 at 25°C. The correction from the above table will be .28 or a total of 7.28. Adding .12 to this gives a corrected reading of 7.40. If the reading is 7.00 at 15°C. the correction from the above table amounts to .22 (to be subtracted) giving 6.78. Adding 0.12 to this gives the corrected reading of 6.90.