Note 6 — VOLUME VI SLICE VIII Conduction, Electric
Reading edition
The samples of silver, copper and nickel employed for these tests were prepared electrolytically by Sir J. W. Swan, and were exceedingly pure and soft. The value for volume-resistivity of nickel as given in the above table (from experiments by J. A. Fleming, Proc. Roy. Soc., December 1899) is much less (nearly 40%) than the value given by Matthiessen’s researches.